Model HFI

Flush Gas Station, For Use with HIR Pyrometer

The Delta Controls Model HFI provides a low, filtered purge gas across the process side of the HIR lens glass to reduce particulates from building up on lens.  The HFI provides a single place at the reactor where the operator can regularly monitor and verify proper operation of the flush gas stream.

Features

  • Accurate continuous control of purge flow rate
  • Insures long term temperature measurement reliability by sweeping dust and ash from the pyrometer lens window
  • Corrosion resistant, suitable for the severe environments found in sulfur recovery units
  • All stainless steel NACE compliance standard
  • Mounts on a vertical surface or 2” pipe stand
  • Labeled connections minimize connection errors
  • Front mounted instructions encourage correct operation which will maximize pyrometer accuracy

Specifications

  • Flow Range: 4-38 LPM (Standard)
  • Pressure Indicator: 2.5”Ø; 0-60 psig (0-4 bar)
  • All stainless steel internal and external parts
  • Flow Control: Constant mass flow rate type
  • Pressure Control Range: 2 to 50 psig (0.1 - 3.5 bar)
  • Filter: 5 micron sintered polypropylene
  • Drain: Manual valve
  • Materials:
    • Meter body: Aluminum with S.S. trim, or all stainless steel
    • Pressure Body: Zinc with S.S. trim, or all stainless steel
    • Connection Fittings: All S.S., 1/8” FNPT pipe or millimeter size tubing
    • Faceplate and Pipe Clamps: Steel, stainless steel optional
  • Supply Pressure: 25 to 250 PSIG (1.7 to 17 bar)
  • Supply Gas: Clean dry air or nitrogen

Applications

The Model HFI Flush Gas Control Station is used with the Model HIR Pyrometer, primarily in Claus Thermal Reactors. The HFI provides a low, filtered purge to the window of the HIR to keep particulates from building up on the HIR window.